Cs-wsp nailing
WebMar 16, 2011 · For bracing Method CS-WSP, a corner, as shown in Figures R602.10.4.4(1) and R602.4.4(2), or some other method of anchoring the wall is required at each end of … http://dev.norbord.com/na/wp-content/uploads/APA_PR-N133_Norbord_TallWall.pdf
Cs-wsp nailing
Did you know?
WebFrom TABLE 1, with two stories above the braced wall line, a 20-foot spacing, and bracing Method CS-WSP, the minimum required length of bracing is 9.5 feet . From TABLE 2, the adjustment factors are: 1.10 for the first of a three-story house with a roof eave-to-ridge height of 15 feet. 0.95 for a wall height of 9 feet. WebPolymer Coated CSP. Polymer coated (AASHTO M245, ASTM A742) is a laminate film that is applied over protective metallic coatings, typically galvanized. The 10/10 grade (10 …
WebJul 14, 2024 · Maumelle, AR. Jul 13, 2024. #1. Builders are substituting insulating foam board for osb. I have them providing CS-WSP at the corners and then CS-PF at garages. However, they are not using a nailing pattern that seems sufficient. Plus studs are … WebThis requirement alone determines the bracing method of the home to be continuously sheathed wood structural panel (CS-WSP). Cripple Wall Bracing. ... For example, not nailing the sheathing to the mud sill as …
WebICC Digital Codes is the largest provider of model codes, custom codes and standards used worldwide to construct safe, sustainable, affordable and resilient structures. Web1 of this report. When using Method CS-WSP, Table 1 provides the minimum permissible lengths and contributing lengths based both on the wall height and the adjacent clear opening height. If an 8- or 9-foot tall wall line is present, Method CS-WSP braced wall segments less than the Table 1 minimum length may be used but with a corresponding
WebMar 31, 2024 · Continuously sheathed wood structural panels (CS-WSP): To simplify things, this is just the exterior sheathing on the home, often floor-to-ceiling plywood or OSB sheets with a specific thickness and structural rating. Areas with windows, doors, or other types of penetrations often do not account toward the braced wall design.
Webattachedraming to f with 8d common nails at 6” o.c. at the edges and 12” o.c. field nailing. ii. Continuous CS-WSP – Continuous Sheathed Wood Structural Panels requires the entire storyheathed with be s WSPs, full height walls as well as above and below openings. Thicknessnd a attachment same as WSP. iii. high bridge waterWebwsp, PBS, PCP. BV-wsp Double sided Actual Single sided 0.5 x Actual Auual SDC B C, design Wind speed < 40 mph AB W D, wind < 140 cs.G Opening 64 cs.wsp, cs-SFB METHOD (See Supporling one story and roof DC A, B C cS-PF SDC D, 25.4 I I hour 0.447 Not 24 header height Actual Actual* 1.5 x Ac 1.5 x Actual' 10 16 24 30 20 20 feet c Note … highbridge ueWebWSP is one of the world's leading engineering professional services firms, with 37,000 talented people, based in more than 500 offices, across 40 countries. We are technical … highbridge water companyWebminimize nail "pop" or "backout by www.APAWOOD.ORG. 2" or 3" O.C. Nailing For Structural Shear Wall Panels Per Structural Plans. 2 Rows of Staggered Nails at Panel Edges 1 Row of Staggered Nails at Panel Top & Bottom Edges high bridge water companyWebConstruction Industry Safety Training. Every day, construction workers put their own safety at risk to complete difficult jobs. These essential tasks include bridge erection, residential … highbridge washington dcWebAug 7, 2024 · In the building code, this is bracing method “CS-WSP,” and it provides the greatest bracing capacity for either wind or seismic loads. … how far is orefield pa from meWebSee Method CS-WSP: CS-PF: Continuous portal frame: See Section R602.10.4.1.1: See Section R602.10.4.1.1: For SI: 1 inch = 25.4 mm, 1 pound per square foot = 47.89 Pa. Applies to one wall of a garage only. Roof covering dead loads shall be 3 psf or less. R602.10.4.1.1 Continuous Portal Frame. how far is orange texas from louisiana